Efficacy testing of biocidal products
Efficacy testing of biocidal products measures how many microorganisms a disinfectant, a preservative or a treated material kills or inhibits under controlled conditions, and shows with data whether the product delivers the biocidal function claimed for it.
As part of our materials analysis and testing services, we evaluate the efficacy of disinfectants, antimicrobial additives and treated articles against bacteria and fungi. We apply standard methods and the adaptations needed to reproduce real use, so the results can support a claim, guide the choice between formulations or validate a manufacturing process.
A biocide that works on the supplier’s data sheet can lose activity when it is diluted, when it meets organic soil or when it is compounded into a plastic processed at high temperature. Measuring its efficacy in the actual matrix and conditions of use prevents launching products with claims that do not hold up.
Talk to a specialist
Request a free initial consultation; contact a consultant from our team of specialists
What is efficacy testing of biocidal products?
What is it?

The efficacy of a biocide is its demonstrated ability to kill, inhibit or prevent the action of harmful organisms under the conditions in which it will be used. An efficacy test exposes a known population of microorganisms to the product for a defined contact time and counts how many survive compared with an untreated control. It shows whether a disinfectant reaches the required reduction, whether a treated plastic or fabric slows bacterial growth and whether that activity survives processing and use.
In the European Union, the Biocidal Products Regulation (EU) 528/2012 governs how biocides are placed on the market and used, and groups them into 22 product types within four main groups: disinfectants, preservatives, pest control products and other biocidal products. The regulation also covers treated articles, such as a fabric or a plastic part that deliberately incorporates a biocide. Authorizing a biocide requires proof of efficacy, and any biocidal property claimed for a treated article is best backed by test data.
The method depends on the type of product and its use: suspension tests for liquid disinfectants, carrier tests for surfaces, contact methods for plastics and other non-porous materials, and dedicated methods for textiles. The variables that weigh most on the result are the test organism and its initial load, the product concentration, the contact time and temperature, the presence of organic soil and the neutralization of the biocide at the end of the test.
Biocidal efficacy testing at INFINITIA
We start from the claim to be demonstrated and from how the product is actually used: which surface or material it acts on, against which microorganisms, at what concentration and over what time. With that information we choose the standard method that fits best and define the adaptations needed for the test to answer that question.
For treated articles, we also check that the biocide survives manufacturing. That was the approach in the integration of a new antimicrobial additive into plastic and elastomer parts, where processing was adjusted to avoid degrading it and its effectiveness in the part was verified under ISO 22196.
For disinfectants, we measure efficacy and the effect on the substrate at the same time, using consistent criteria for concentration, application and contact time. That is how we handled the comparison of electrolyzed water with commercial products on delicate floors, which had to confirm equivalent performance without damaging the material.
We deliver a technical report with the method used, the test organisms, the contact conditions, the counts against the control and the log reduction or antibacterial activity obtained. When the result falls short of the target, the report points out which variable to review: the dose, the contact time or the processing of the material.
Benefits of biocidal efficacy testing for backing claims and choosing formulations
Benefits
The main benefit is being able to back every efficacy claim with data. A result obtained with a recognized method, with its controls and under defined conditions can be presented to a customer, a distributor or an authority, and avoids withdrawing or reformulating a product when someone questions what it promises.
It supports choosing a formulation or additive on technical grounds. Comparing several concentrations or suppliers with the same method shows which one reaches the required reduction at the lowest dose, cutting the cost of active substance and the exposure of users and the environment without giving up performance.
It detects efficacy losses before they reach the market. A treatment can work when freshly applied and lose activity with cleaning or wear, which is why the approval of antimicrobial materials for demanding applications assessed activity after accelerated cycles of use, cleaning and environmental exposure.
It reduces risk in use. Knowing which microorganisms the product controls and with what contact time makes it possible to write realistic instructions and prevent an insufficient dilution or time from leaving surfaces contaminated in food, healthcare or public areas.

Types of biocidal efficacy tests by product and use
Types
There is no single efficacy test: each type of biocidal product is evaluated with the method that reproduces the way it acts. A liquid disinfectant is tested in suspension and on surfaces, while a treated material is evaluated through direct contact with the inoculum.
The selection criterion combines the claim to be demonstrated, the substrate, the target microorganisms and the conditions of use. When no standard method reproduces those conditions well, the closest one is adapted and every change is documented so the result remains comparable.
Suspension tests for disinfectants
A suspension test mixes the disinfectant, at its in-use concentration, with a suspension of reference bacteria and an interfering substance that simulates clean or dirty conditions. The EN 1276 standard applies it to disinfectants used in food, industrial, domestic and institutional areas and requires a reduction of at least 5 log (99.999%) within the specified contact time.
| Test | Product | Result | Contact |
|---|---|---|---|
| Suspension | Liquid disinfectant | Log reduction | Minutes |
| Surface | Applied disinfectant | Log reduction | Minutes |
| Contact | Non-porous material | Antibacterial activity | Hours |
| Textile | Treated fabric | Antibacterial activity | Hours |
| Fungal growth | Treated material | Growth rating | Weeks |
It is the first step for a formulation: the surface test comes afterward, once the suspension test has been passed. It allows concentrations, contact times and batches to be compared, and shows the effect of water hardness or organic soil. The table summarizes how it differs from the other methods.
Surface tests for disinfectants
A surface test places the inoculum on non-porous carriers, usually stainless steel, lets it dry and then applies the disinfectant for the intended contact time. The EN 13697 standard defines it for the bactericidal, yeasticidal and fungicidal activity of disinfectants used in food, industrial, domestic and institutional areas without mechanical action, and requires somewhat lower reductions than the suspension test because dried bacteria on a substrate are harder to kill.
It can be adapted to the actual substrate (plastics, ceramics, flooring or coatings) and to the application method. On sensitive surfaces it is worth measuring efficacy and the effect of the product on the finish at the same time, so as not to choose a disinfectant that works but damages the material.
Antibacterial activity of treated plastics and surfaces
The ISO 22196 standard evaluates the antibacterial activity of plastics and other non-porous surfaces treated with an antibacterial agent. The inoculum is covered with a film that keeps it in contact with the surface and, after incubation, the count on the treated sample is compared with that on an untreated reference. The log difference between the two is the antibacterial activity (R).
The result depends on the additive being present and available at the surface, so it is worth pairing it with the characterization of additives and fillers when activity is lower than expected. The standard does not cover textiles, photocatalytic materials or untreated surfaces.
Antimicrobial efficacy of treated textiles
Fabrics with an antibacterial finish, used in technical clothing, uniforms, upholstery or healthcare textiles, are tested to ISO 20743, because their porous structure holds the inoculum differently from a plastic. The standard offers three ways of inoculating the sample (absorption, transfer and printing), chosen according to the fabric and its use, and compares bacterial growth on the treated fabric with that on an untreated one.
Laundering is the critical variable: a finish that works on new fabric can lose activity after several cycles. That is why it is worth repeating the test after standardized washes or under real conditions of use and recording how many washes the claimed activity withstands. When the finish is marketed as odor-control, what is demonstrated is its effect on the bacteria that cause the odor.
Resistance of treated materials to fungi and biofilms
Plastics, paints, sealants and coatings incorporate preservatives or fungicides to prevent mold growth in damp environments. For plastics, the ISO 846 standard exposes specimens to spores of reference fungi under favorable humidity and temperature for several weeks, and assesses growth by visual inspection and by changes in mass or properties compared with an untreated sample.
When the problem is biofilm formation in pipes, equipment or wet surfaces, the study is extended with microbiology, antimicrobial efficacy and biofilm tests, which measure how these microbial communities attach and how they are removed. The result guides the choice of preservative, its dose and the cleaning frequency required.
Efficacy of ultraviolet, ozone and steam disinfection equipment
Equipment that disinfects by physical means or by generating the agent on site also needs to prove its efficacy. For automated processes that diffuse a chemical disinfectant through the air, such as ozone or hydrogen peroxide, the reference is EN 17272: inoculated carriers are placed at different positions in the room, the full cycle is run with no one present and the reduction is measured at each point.
The dose reaching each area drives the result: with ultraviolet light, shadows and distance matter; with ozone, concentration and exposure time. Ultraviolet light and steam, which fall outside that standard, are evaluated by adapting the same carrier-based approach. The article on ozone disinfection of surfaces, air and odors explains the principle behind this technique.
Industries where biocidal efficacy protects products, processes and users
Sectors
Biocidal products and treated articles are used wherever microbial contamination compromises safety, hygiene or durability. Each industry has its own target microorganisms, substrates and conditions of use.
That is why the same disinfectant or additive may need different tests depending on where it is applied, and why the method should be defined from real use before results are compared.
Efficacy testing of biocidal products in food and agriculture: surface disinfectants and packaging
In food processing, disinfectants act on steel surfaces, conveyor belts and utensils carrying organic residues, and active packaging incorporates antimicrobial agents to extend the shelf life of the packaged product.
- Dirty conditions: fat and protein residues reduce efficacy and must be included in the test conditions.
- Target microorganisms: the pathogens of concern in the process guide the choice of test strains.
- Contact time: it must fit the line’s cleaning and production schedule without lengthening downtime.
Suspension and surface tests with an interfering substance show whether a disinfectant performs on the line, a key point for preventing and controlling Listeria in food production.
Efficacy testing of biocidal products in healthcare and pharma: surfaces, textiles and devices
Hospitals, care homes, laboratories and pharmaceutical plants combine surface disinfectants, treated textiles and antimicrobial materials in furniture, equipment housings and items in frequent contact with patients and staff.
- Medical area: disinfectants for healthcare use are evaluated with their own methods, separate from food and industrial ones.
- Contact surfaces: treated handles, rails and housings need to show activity after daily cleaning with the facility’s products.
- Textiles: treated uniforms and curtains must retain their activity after industrial laundering.
Contact tests on treated materials and textile tests after laundering provide comparable data to support the choice of an antimicrobial material for high-touch areas in wards and common spaces.
Efficacy testing of biocidal products in automotive and mobility: cabins and public transport
In vehicles and public transport, controls, dashboards, upholstery and grab handles collect microorganisms in an enclosed, poorly ventilated space, and manufacturers turn to treated plastics and fabrics or to cabin disinfection systems.
- Interior plastics: the additive must withstand injection molding temperatures without losing activity.
- Upholstery and textiles: activity is measured after aging and after cleaning the cabin with the usual products.
- Disinfection equipment: ozone or ultraviolet light must reach the shadowed areas of the interior.
Testing materials and equipment under conditions representative of the cabin makes it possible to compare solutions on the same basis before choosing the one that goes into the production vehicle.
Efficacy testing of biocidal products in plastics and rubber: antimicrobial additives in parts and compounds
Plastic and elastomer compounds incorporate antimicrobial additives, such as silver, zinc or copper based agents or organic biocides, to prevent staining, odors and biofilms on parts that are handled or in contact with water.
- Processing: temperature and shear can degrade the additive during compound extrusion or injection molding.
- Dosing: the masterbatch let-down ratio sets how much active agent reaches the part.
- Surface availability: the agent must reach the exposed surface to act on the bacteria that settle on it.
Contact tests on plaques molded with the final formulation and process measure the real activity of the part and allow the dose and processing to be fine-tuned.
Efficacy testing of biocidal products in home and consumer goods: cleaning, textiles and appliances
Cleaning products with a disinfecting action, odor-control textiles and appliances with hygienic surfaces or cycles reach consumers with claims that need to be demonstrable with a recognized method.
- Cleaning products: efficacy is measured at the dilution and contact time stated on the label.
- Appliances: treated seals, trays and reservoirs must keep their activity in the damp, warm environments where they operate.
- Home textiles: on treated towels and bedding, tests check whether the activity withstands home laundering.
Measuring efficacy under label conditions avoids claims that a competitor or a consumer authority could challenge, and makes it easier to benchmark the product against competing ones.
Efficacy testing of biocidal products in the chemical industry: disinfectants, preservatives and coatings
Formulators of disinfectants, in-can preservatives and functional coatings need efficacy data to set the concentration of the active substance and compare their formulation with alternatives before scaling it up.
- Concentration setting: testing several doses shows the lowest one that reaches the target with enough margin.
- Formulation compatibility: surfactants, solvents and pH can boost or cancel the activity of the active substance.
- Stability: efficacy is also checked on aged samples to set the shelf life of the packaged product.
Suspension tests, being fast and comparable, make it possible to screen several formulations in parallel and keep surface or end-use tests for the shortlisted candidates.
Efficacy testing of biocidal products under real conditions as a basis for decisions
Value
A well-designed efficacy test answers two questions at once: whether the product delivers what it claims, and under which conditions it stops doing so. The first supports sales and approval; the second guides formulation, dosing and instructions for use.
Testing before launch avoids decisions based solely on the active substance supplier’s data sheet. An additive that is effective in its masterbatch can fall below the threshold in the finished part, and a disinfectant that passes the suspension test can fail on a porous or soiled substrate. Catching this during development costs far less than recalling a batch, changing the labeling or redoing the technical documentation of a product already on the market.
In food, healthcare and public settings, efficacy results are part of the technical documentation that customers and auditors ask for. We work with reference strains of bacteria and fungi in our biosafety level 2 microbiology room, apply standard methods where they exist and document every adaptation when real use calls for departing from them, so the result can be defended before third parties. Each report records the strains, conditions and controls, so the test can be reproduced and compared later.
If you are about to launch a disinfectant, add an antimicrobial agent to a material or defend a claim before a customer, send us samples of the product or treated material together with an untreated reference, the technical data sheet, the in-use concentration and the claim you need to demonstrate. We define the method and test organisms with you, and deliver a technical report with the counts, the reduction achieved and the conclusion against your target.

Frequently asked questions about efficacy testing of biocidal products
FAQs
What does a biocidal efficacy test not prove?
An efficacy test proves the product’s activity against the organisms tested and under the conditions of the method, but it does not extend that activity to other organisms, substrates or contact times. ISO 22196 itself states that its results do not reflect activity under other conditions of temperature, humidity or nutrients.
It also does not replace the authorization of the biocide, and it says nothing about durability unless the test is repeated after use or cleaning. That is why the claim to be supported should be defined first, and the method, strains and conditions chosen to cover it, rather than interpreting afterward a result obtained for a different question.
How does a biocidal product differ from a treated article?
A biocidal product is a substance or mixture placed on the market to destroy, deter or render harmless harmful organisms, such as a disinfectant. A treated article is a material or product into which a biocide has been deliberately incorporated or onto which it has been applied, such as a plastic with an antibacterial additive or a fabric with an antimicrobial finish.
Regulation (EU) 528/2012 treats an article whose primary function is biocidal as a biocidal product, and requires specific labeling when a treated article makes a biocidal claim. The distinction shapes the test method: the product is tested at its in-use concentration and the article in its final form.
Which microorganisms are used in an efficacy test?
Each method defines reference strains that represent groups with different levels of resistance. ISO 22196 uses Staphylococcus aureus and Escherichia coli, and EN 1276 adds Pseudomonas aeruginosa and Enterococcus hirae to cover bacteria that are more resistant to disinfectants.
When the application calls for it, fungi, yeasts or process-specific microorganisms are added, provided their handling is compatible with the biosafety level of the facility. The choice starts from the claim and the real risk, and microbiological analyses of the plant or product help identify which organisms should be included. Strains are maintained under controlled conditions so their behavior stays consistent from one test to the next.
Is a standard test or a test adapted to real use better?
A standard test provides comparability: another laboratory can repeat it, and a customer or an authority recognizes the method. Its limitation is that it sets generic conditions of time, temperature and substrate that may not match those of the product.
An adapted test modifies those conditions to reproduce use, for example with the actual substrate, a specific organic load or a shorter contact time. Combining both is the most useful approach: the standard test supports the claim and the adapted one shows how the product behaves where it will be used. Every adaptation is documented in the report.
What are clean and dirty conditions in a disinfectant test?
They are two levels of interfering substance, usually bovine albumin at different concentrations, added to the test to simulate the organic matter present on a surface. Clean conditions represent a surface that has been washed before disinfection, and dirty conditions represent direct application over soil residues.
The choice has a real impact on the result: organic matter consumes or blocks part of many biocides, such as chlorine-based ones, and a product that passes under clean conditions may fail under dirty ones. Testing should therefore reflect the facility’s protocol and take into account the surface disinfection methods applied there.
How can antimicrobial activity be shown to last in use?
By subjecting samples to representative aging or wear and repeating the efficacy test before and after. Cycles can include cleaning with the usual products, abrasion, laundering and exposure to light or humidity, depending on how the material is used. The number of cycles and the interval between them are set according to the expected service life.
The comparison shows whether activity is retained, declines gradually or disappears after the first cycles, which indicates whether the agent stays at the surface or is depleted. Abrasion, scratching and easy-cleaning tests apply that wear in a controlled way before efficacy is measured again.
What is neutralization and why does it affect the result?
Neutralization stops the action of the biocide at the end of the contact time, using a chemical neutralizer or filtration. Without it, the product would keep acting during the count, and the test would attribute to the contact time an efficacy that actually occurs afterward.
That is why standard methods require checking that the neutralizer works and is not toxic to the test organisms. It is a control that does not appear on the commercial data sheet and that explains part of the differences between results from different sources, especially with persistent biocides such as silver or quaternary ammonium compounds.
How should a log reduction be interpreted?
Each log unit means dividing the number of viable microorganisms by ten: a 3 log reduction removes 99.9% and a 5 log reduction removes 99.999%. It is the usual way of expressing the efficacy of disinfectants and the antibacterial activity of materials.
The figure only makes sense together with the method, the strain, the contact time and the required value. In ISO 22196 activity is calculated against the untreated reference after incubation, and in EN 1276 against the initial load. Two identical reductions obtained with different methods cannot be compared with each other.
How much does biocidal efficacy testing cost and what does it depend on?
It depends on the method, the number of test organisms, concentrations and contact times, the replicates and whether the test needs to be adapted or the samples aged beforehand. A standard test against two strains costs considerably less than a comparative study of several formulations with prior wear.
For a firm quote, tell us which product or material you want to test, which claim you need to support, how many samples you have and whether there is a standard or customer specification you must meet. With that information we will propose the test plan that best fits your goal.
How long does it take to get results?
Typical lead times range from 1 to 4 weeks, depending on the method, the number of samples and whether specimens need to be prepared or aged before testing. Incubation sets a minimum time that cannot be shortened, and fungal tests, which take several weeks, sit at the upper end of that range or go beyond it.
If you need the result urgently, a 24 to 72 hour service can be considered depending on the case, when the method allows it. Tell us the date you need the data and send the samples already prepared and labeled, because shipping time also counts.
Why does the additive supplier claim efficacy when the part does not show it?
Because the supplier’s data sheet reflects tests of the additive in its own matrix and concentration, which the finished part does not always reproduce. During extrusion or injection molding, heat can degrade the agent, the masterbatch let-down can fall short and part of the additive remains trapped inside, away from the surface.
Before filing a complaint, it is worth testing the actual part against a reference without additive and checking that the agent is present in the expected amount. If activity is low, the problem may lie in dosing, processing or formulation, and each cause has a different fix.
Which samples should I send and how should I prepare them?
For treated materials, send flat specimens of the finished part or material and, whenever you can, equivalent untreated specimens as a reference. For disinfectants, send the product in its original container with the stated in-use concentration and contact time. The quantity and size depend on the method, and we will specify them in the proposal.
Handle the samples with gloves, do not clean them with products that may leave residues, and pack them separately. Tell us the claim you want to demonstrate, the reference standard or specification and any prior treatment, such as laundering or aging, that we should apply before testing.